Power line sag monitoring device
Contact Info
- Add:Room C-9, Building C, Precision达 Industrial Park, No.39 Qingfeng Avenue, Longgang Sub-district, Longgang District, Shenzhen City, Zip: 518116
- Contact: 小李
- Tel:18820479231
- Email:2512646832@qq.com
Other Products
Alternative product names: Power Line Sag Monitoring Device, Conductor Sag Monitoring System, Power Grid Line Sag Monitoring Device, High-Voltage Line Sag Monitoring Device
I. Introduction
With the continuous expansion of power networks, transmission lines, as key energy transmission infrastructure, are exposed to complex environmental impacts over long periods. High temperatures increase conductor sag, which can easily lead to accidents, while severe weather can also cause abnormal sag, and traditional patrol inspections struggle to address these issues. Failures caused by sag problems will interrupt power supply and result in losses, so the urgent need to introduce an intelligent monitoring device has become a critical requirement for ensuring power grid safety.
II. Overview
The TLKS-PMG-HC Power Grid Line Sag Monitoring Device launched by Telcom is an advanced device integrating intelligent monitoring and efficient early warning. It combines cutting-edge technology to continuously and accurately monitor the sag status of transmission line conductors, capturing subtle sag changes in a timely manner, providing reliable data support for power grid operation and maintenance personnel, effectively preventing various safety accidents caused by abnormal sag, and building a solid technical defense line for the stable operation of the power system.
III. Working Principle
The Power Grid Line Sag Monitoring Device uses a sag sensor to real-timely and accurately monitor the minimum distance between the conductor and the ground, the horizontal angle of the conductor at the outlet of the clamp, and the sag status of the conductor. Once abnormal sag is detected, the system will immediately send early warning information via 4G/WIFI optical fiber network to remind managers to take timely measures, effectively preventing potential safety risks.
IV. Core Functions
1. High-Precision Monitoring Technology: Adopts advanced sag sensors to real-timely and accurately monitor the minimum distance between the conductor and the ground, the horizontal angle of the conductor at the outlet of the clamp, and the sag status of the conductor, ensuring data accuracy.
2. Automated Data Collection: The system has an internal timing collection mechanism, set to automatically collect data every 30 minutes by default, and supports remote command control to achieve real-time data acquisition and analysis.
3. Intelligent Early Warning System: Once abnormal sag is detected, the system will immediately send early warning information through multiple channels to remind managers to take timely measures, effectively preventing potential safety risks.
4. Intelligent Battery Management: Integrates battery voltage monitoring function to ensure the device operates stably in complex environments and extends its service life.
5. Secure Data Transmission: Uses advanced encryption technology to ensure the security of data transmission, and seamlessly connects with provincial company platforms to achieve data sharing and efficient utilization.
V. Technical Parameters
1. Power Supply Mode: Solar energy + lithium battery
2. Communication Mode: Supports adaptive access to China Telecom, China Unicom, and China Mobile, and operators can be selected according to on-site conditions
3. Working Voltage: DC12V
4. Working Current: <50mA
5. Standby Time: >30 days
6. Distance Measurement Range: 0m-200m
VI. Installation Method
The TLKS-PMG-HC Power Grid Line Sag Monitoring Device is designed with full consideration of installation convenience and flexibility, suitable for various monitoring scenarios:
1. Jumper Sag Monitoring: The sensor is directly fixed on the jumper to accurately capture sag changes and ensure monitoring precision.
2. Insulator Sag Monitoring: The sensor can be installed at both upper and lower ends of the insulator string to achieve full-coverage monitoring without dead angles.
3. Inter-Phase Sag Monitoring in Span: Install the sag monitoring device between two conductors that need to be monitored to achieve real-time monitoring of inter-phase sag and enhance power grid safety.
VII. Conclusion
In the journey of the power industry moving toward intelligence and high efficiency, Telcom has always been at the forefront, driving development through innovation. The TLKS-PMG-HC Power Grid Line Sag Monitoring Device, with its leading technology, excellent performance, and comprehensive services, has become a reliable assistant for power grid safety operation and maintenance. In the future, we will continue to deepen the power technology field, continuously optimize products and services, inject strong impetus into the high-quality development of the power industry, and safeguard the brightness and tranquility of thousands of households. Products are customizable. The quoted price is a reference price at the time of market release; the actual price is subject to negotiation. For more product information, please contact Telcom Technology Manager Li 1/8/8/2/0/4/7/9/2/3/1 WeChat and QQ are synchronized
| Industry Category | Machinery & Equipment/Hydraulic Transmission/Filtration Monitoring Devices |
|---|---|
| Product Category | |
| Brand: | 特力康 |
| Spec: | TLKS-PMG-HC |
| Stock: | 999 |
| Manufacturer: | 深圳市特力康科技有限公司 |
| Origin: | 114403 |